WLAN Card Installation Guide
Menu screen What the options mean
Communication Protocol. Selects the mode of Bi-Directional communications. In most cases this
menu does not need to be altered and is meant to help support legacy applications which may
have incorporated older bi-directional statuses. Anything other than Staus 5 or Standard (none) is
not recommended.
Comm. P
otocol
Status 5*
Host Interface
Ethernet*
represented in the interface specifications. For more information, refer to the appropriate
section in the programming and interface guide.
• Standard - bi-directional interface is not used.
• Status 2 - legacy bi-directional support. Not recommended for new applications.
• Status 3 - legacy bi-directional support. Not recommended for new applications.
• Status 4 - legacy bi-directional support. Not recommended for new applications.
There are only two options relative to the serial interface, ignore all others.
• Auto Switching - the printer automatically switches to the relative interface type and moves
into the applicable menus.
• Ethernet - factory default. Allows the operator to select the interface and the relative menus
will follow.
Is a transitional screen that allows entr
into the Net BIOS Protocol menu.
ETHERNET SETTING
NetBIOS P
otocol
NetBIOS P
otocol
Enable*
llows determina
ion of if the NIC will recognize the NetBIOS pro
ocol.
• Enable - factory default. Will recognize.
• Disable - will not reco
nize.
ASCII Data Po
t
1024*
This options allows for the port number to be set for ASCII print jobs. The data port number must
match the host computer setting.
The allowable ran
e is 0 to 65535
and the factor
default is 9100.
Keep Ali
e Time
3 minutes*
Determines the amount of time that the tcp connection will remain connected after the print job
has terminated.
The allowable ran
e is 2 to 10 minutes
and the factor
default is 3 minutes.
Ethernet Speed
Auto Select*
This menu appears only if a 10/100Base-t Network Interface Card (NIC) is installed. There are
five different speed modes to allow compatibility with different systmes and networks.
• Auto Select - factory default. Tells the 10/100Base-T NIC to perform an automatic detection
scheme and configure itself to be one of the other allowable options.
• 10 Half Duplex - communicates at 10 megabytes per second using half duplex.
• 10 Full Duplex - communicates at 10 megabytes per second using full duplex.
• 100 Half Duplex - communicates at 100 megabytes per second using half duplex.
• 100 Full Du
lex - communicates at 100 me