SATO D508 Wartungshandbuch Seite 132

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 290
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 131
Unit 4: Standard Command Codes
E/Pro Programming Reference
4-80 PN: 9001096E
2D50 (DATA MATRIX - ECC200)
FUNCTION
Specifies Data Matrix (ECC200) of 2D code.
FORMAT
<ESC>2D50,aa,bb,ccc,ddd <ESC>DNmmmm,n...n
a = Cell width (01 to 16 dots)
b = Cell height (01 to 16 dots)
c = Quantity of cells per line (000 fixed)
d = Quantity of cell lines (000 fixed)
m = Data size (1 to 3116 bytes)
n=Print data
Specify 7EH, 00H when printing 00H
Specify 7EH, 7EH when printing 7EH
Between <ESC>A and <ESC>Z but following <ESC>H and <ESC>V.
EXAMPLE
Example - Cell width: 3 dots, Cell height: 3 dots.
<ESC>A
<ESC>V100<ESC>H200
<ESC>2D50,03,03,000,000
<ESC>DN0010,0123456789
<ESC>Z
OUTPUT
(4-51)
NOTES
When designating a parameter other than specified or when the print data quantity does not match,
printing will not be performed.
When selecting the print format, leave more than 2mm margin around Data Matrix to be properly read
by scanner.
Data Format - Numeric: 3116, Alphanumeric: 2335, Binary (01H-FFH): 1556.
Refer to Appendix: Reference Table 38 for additional information.