SECTION 3.
CONFIGURATION
PRINTER DIP SWITCH CONFIGURATION
DIP Switch Panels
There are three DIP switches (DSW1, DSW2 and DSW3). These are located inside the
cover. These switches can be used to set:
RS232C transmit/receive parameters
Thermal transfer or direct thermal mode
Label sensor enable/disable
Head check mode
Hex dump mode
Receive buffer size
Operation mode
Each switch is an eight section toggle switch. The ON position is always to the top. To
set the switches, first power the unit Off, then position the DIP switches. Finally, after
placing the switches in the desired positions, power the printer back on. The switch
settings are read by the printer electronics during the power up sequence. They will
not become effective until the power is cycled.
RS232 Transmit/Receive Setting
Data Bit Selection (DSW1-1). This switch sets the printer to receive either 7 or 8
bit data bits for each byte transmitted.
Parity Selection (DSW1-2, DSW1-3). These switches select the type of parity
used for error detection.
DSW1-1 SETTING
Off 8 data bits
On 7 data bits
12345678
ON
OFF
DSW1
DSW1-2 DSW1-3 SETTING
Off Off No Parity
Off On Even
On Off Odd
On On Not Used
12345678
ON
OFF
DSW1
SATO “S” Print Engines 9001034 Rev E Page 3-1